Grid Monte Carlo Simulation of a Medical Linear Accelerator
##plugins.themes.bootstrap3.article.main##
A full grid simulation of the head of an Elekta Synergy Platform medical linear accelerator is performed using the Geant4 Monte Carlo platform. The simulation includes all components of the accelerator head and a homogeneous water phantom. Results in terms of depth doses and lateral dose profiles are presented for 6 MV photon beam with the 10x10 cm2 reference field size at 100 cm distance from the source. Overall, a good agreement with the measured dose data is achieved with a precision better than 0.93% and 2.63% for the depth dose profile and lateral dose profiles respectively.
Downloads
Download data is not yet available.
References
-
A. Dotti, 2012, Validation of Geant4 Releases with distributed resources. Journal of Physics: Conference Series 396 032033.
Google Scholar
1
-
J. Apostolakis et al, 2009. Geometry and physics of the Geant4 toolkit for high and medium energy applications Workshop on Use of Monte Carlo Techniques for Design and Analysis of Radiation Detectors, Radiat. Phys. Chem.78 859–73.
Google Scholar
2
-
Geant4 User's Guide for Application Developers by Geant4 Collaboration, Version: geant4 10.3, Publication date 9 December 2016.
Google Scholar
3
-
Vishwanath P. Singh, M.E. Medhat, N.M. Badiger, Photon energy absorption coefficients for nuclear track detectors using Geant4 Monte Carlo simulation. Radiation Physics and Chemistry, Volume 106, January 2015, Pages 83-87.
Google Scholar
4
-
M.S. Teixeira and al. da Rosa. Monte Carlo simulation of Novalis Classic 6 MV accelerator using phasespace generation in GATE/Geant4 code. Progress in Nuclear Energy, Volume 110, January, 2019, Pages 142-147. https://doi.org/10.1016/j.pnucene.2018.09.004
Google Scholar
5
-
S. Agostinelli and al. 2003. "Geant4 a simulation toolkit". Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 506 (3): 250.
Google Scholar
6
-
Geant4-Collaboration 2009 Physics Reference Manual for Geant4 CERN: http://www.geant4.org/geant4/support/index.shtml.
Google Scholar
7
-
Andreas Schälicke et al, 2011: Geant4 electromagnetic physics for the LHC and other HEP applications: Journal of Physics.: Conf. Ser. 331 032029 doi:10.1088/1742-6596/331/3/032029.
Google Scholar
8
-
Geant4 Virtual Organization, https://lcgvoms.cern.ch:8443/vo /geant4/vomrs.
Google Scholar
9
-
Morocco Grid Computing, http://magrid.ma/.
Google Scholar
10
-
Ph Canal et al, 2010, Support for significant evolutions of the user data model in ROOT files, J. Phys.: Conf. Ser. 219 032004 doi:10.1088/1742-6596/219/3/032004.
Google Scholar
11
-
R. Brun and F. Rademakers, “ROOT—an object oriented data analysis framework,” in Proceedings of the AIHENP Workshop on Nuclear Instruments and Methods in Physics Research A, pp. 81–86, Lausanne, Switzerland, September 1996.
Google Scholar
12
-
I. Antcheva et al., ROOT A C++ framework for petabyte data storage, statistical analysis and visualization, Computer Physics Communications, Volume 180, Issue 12, December 2009, Pages 2499-2512.
Google Scholar
13
-
Chetty, I.J et al., 2007. Report of the AAPM task group No. 105: Issues associated with clinical implementation of Monte Carlo-basedphoton and electron external beam treatment planning. Med. Phys. 34, 4818–4853.
Google Scholar
14
-
Edwin Sham, Jan Seuntjens, Slobodan Devic, Ervin B Podgorsak, Influence of focal spot on characteristics of very small diameter radiosurgical beams, Med. Phys. 35, 3317 (2008); http://dx.doi.org/10.1118/1.2936335.
Google Scholar
15
-
Verhaegen F and Seuntjens J, 2003. Monte Carlo modelling of external radiotherapy photon beams, Phys. Med.Biol.48R107–64.
Google Scholar
16
-
Grevillot. L et al. D, 2011. Simulation of a 6 MV Elekta Precise Linac photon beam using GATE/GEANT4, Phys. Med. Biol. 56 903.
Google Scholar
17
-
S.Didi, A.Moussa, Y. Tayalati, M. Zerfaoui, “Simulation of the 6 MV Elekta Synergy Platform linac photon beam using Geant4 Application for Tomographic Emission”, Journal of Medical Physics. 2015; 40(3):136-143. doi:10.4103/0971-6203.165077.
Google Scholar
18
-
Eadi W.T. et al., Statistical methods in experimental physics (North-Holland, Amsterdam, 1971)269.
Google Scholar
19
-
Followill DS, Taior RC, Tello VM, Hanson WF. An empirical relationship for determining photon beam quality in TG-21 from a ratio of percent depth doses. Med Phys. 1998;25(7 Pt 1):1202–05.
Google Scholar
20
-
Bak J.et al,2012. Modified dose difference method for comparing dose distributions, Journal of Applied Clinical Medical Physics, Vol. 13, No. 2, Spring 2012.
Google Scholar
21
-
F.M. Khan. The physics of radiation therapy. 2003.
Google Scholar
22
-
M. Zerfaoui, A. Rrhioua, A. Moussa, S. Didi, Y. Tayalati, M. Hamal. “GEANT4 Simulation of 192Ir Source to Study Voxelization and Number of Event Effect on the Dose Distribution”, Lecture Notes in Electrical Engineering, vol 381-2016. Springer, Cham.
Google Scholar
23